1. The pump delivers against an excessively high
discharge pressure
- open discharge valve further until the duty point
conditions have been attained (adjusted)
2. Excessively high back pressure
- fit an oversize impeller2)
- increase rotational speed
(applies to turbine or I.C. engine driven pumps)